AmpHour Calculator

This tool allows you to get the maximum current and time duration that a battery can put out.  You can specify the time in 24-hour format. So if you know the amp-hour capacity and the load you can then determine the time it will be running stable. It even intergrades with NL5 Circuit Simulator.
More calculators coming soon!
program amphour;
{$APPTYPE Console}
{$RESource ahres.res}
uses
windows,
  SysUtils,urlmon,math,
  Classes;

type TNL5=record
FirstValue,LastValue:extended;
HError:hresult;
data:string;
end;
var CONST_HOUR_VALUE,hdt:TDateTime;
ah,a,h:extended;
sh,sah,sa,sd:string;
dd,mIndex,i:integer;
nl5opt:tstringlist;
nl5:tnl5;
function StrToFloatDef(const S:String; def:extended):extended;
begin
try result:=strtofloat(s) except result:=def; end;
end;

function nl5requestoutput(nl5opt:tstringlist;param:string;outp:extended):TNL5;
var nl5filen,nl5url:array[0..max_path]of char;
nl5ans:tstringlist;
begin
result.HError:=urldownloadtocachefile(nil,strfmt(nl5url,
'http://localhost:%u/?%s=%g',[strtointdef(nl5opt.values['nl5port'],80),
nl5opt.values[param],outp]),nl5filen,max_path+1,0,nil);
if nl5.HError=s_ok then begin
nl5ans:=tstringlist.Create;
nl5ans.LoadFromFile(nl5filen);
result.data:=nl5ans.Text;
nl5ans.Free;
end;
end;

function nl5requestinput(nl5opt:tstringlist;param:string;intype:char):tnl5;
var nl5filen,nl5url:array[0..max_path]of char;
nl5ans:tstringlist;
begin
result.HError:=urldownloadtocachefile(nil,strfmt(nl5url,
'http://localhost:%u/?%s(%s)',[strtointdef(nl5opt.values['nl5port'],80),intype,
nl5opt.values[param]]),nl5filen,max_path+1,0,nil);
if nl5.HError=s_ok then begin
nl5ans:=tstringlist.Create;
nl5ans.LoadFromFile(nl5filen);
result.data:=nl5ans.Text;
nl5ans.CommaText:=nl5ans[0];
result.FirstValue:=strtofloatdef(nl5ans[0],0);
result.LastValue:=strtofloatdef(nl5ans[nl5ans.count-1],0);
nl5ans.Free;
end;
deletefile(nl5filen);
end;
label mysub;
begin
if paramstr(1)='/?'then begin
writeln('Usage: ',extractfilename(paramstr(0)),' [nl5port=port nl5options]');
writeln('nl5port=port     Spefifies the HTTP Link port.(default port 80)');
writeln;
writeln('NL5 Options:');
writeln('bat_loadinp=     Spefifies the NL5 component to get its battery load current from');
writeln('bat_loadout=     NL5 Current Source to set the amphour load.');
exitprocess(0);
end;
SetConsoleTitle('AmpHour Calculator');
const_hour_Value:=EncodeTime(1,0,0,0);
nl5opt:=tstringlist.Create;
for i:=1to paramcount do nl5opt.Add(paramstr(i));
mysub:
sh:='0';sa:='0';sah:='';sd:='0';hdt:=0;
writeln('Leave one answer blank');
write('Enter Discharge time(hh:mm:ss):');
readln(sh);
if sh<>'' then begin
write('Enter discharge days(optional):');
readln(sd);
if sd='' then sd:='0';
end;
write('Enter AmpHour rating(in Amphours):');
readln(sah);
if(nl5opt.Values['bat_loadinp']='')and(nl5opt.Values['bat_loadout']='') then begin
write('Enter current draw in Amps:');
readln(sa);
end else begin if nl5opt.Values['bat_loadinp']<>''then begin nl5:=nl5requestinput(
nl5opt,'bat_loadinp','I');
sa:=floattostr(nl5.LastValue);
if nl5.herror<>s_ok then begin writeln('URLErr:',inttohex(nl5.herror,0));
exitprocess(1);end;
end;
end;
if sa='' then sa:='0';
if sah='' then sah:='0';
a:=StrTofloat(sa);
ah:=strtofloat(sah);
if ((sh='')and(ah=0))or((ah=0)and(a=0))or((sh='')and(a=0))then begin
writeln('Error in one or more variables, please check to make sure only numbers are entered and only one answer is blank');
write('Try Again(Yes/no)? ');
readln(sh);
if pos('Y',Uppercase(sh))>0 then goto mysub else exitprocess(0);
end;
if sh<>'' then
try
 hdt:=dd+StrToTime(sh);
except on e:exception do begin
writeln('Error:',e.message);
write('Try Again(Yes/No)?');
readln(sh);
if pos('Y',uppercase(sh))>0 then sh:= 'TRY_AGAIN' else sh:= 'EXIT';
end;
end;
if sh='TRY_AGAIN' then goto mysub;
if sh='EXIT' then exitprocess(0);
if a*ah*hdt<>0 then begin
writeln('You didnt leave any answer blank');
write('Try Again(Yes/No)?');
readln(sh);
if pos('Y',uppercase(sh))>0 then goto mysub else exitprocess(0);
end;
if sh='' then
hdt :=(ah/a)*const_hour_value;
h:=hdt/const_hour_value;
if a=0 then a:=ah/h;
if ah=0 then
ah:=a*h;
nl5:=nl5requestoutput(nl5opt,'bat_loadout',a);
if nl5.HError<>s_ok then writeln('URLErr:',inttohex(nl5.HError,0));
Writeln('Duration: ',Trunc(hdt),' days ',formatdatetime('hh:mm:ss',hdt));
writeln('AmpHour Rating:',floattostr(ah));
writeln('Current Draw:',floattostr(a),' Amps');
write('Do you want to try again(Yes/No)?');
readln(sh);
if pos('Y',Uppercase(sh))>0 then goto mysub;
end.                                   

Published by Justin Roeder

I am an electronics engineer and computer programmer that has autism. I learned by myself

Join the Conversation

1 Comment

Leave a comment

Leave a Reply to Gale Deitch Cancel reply

Your email address will not be published. Required fields are marked *

seventeen − nine =

All in one
Start
Amazon.com, Inc. OH Dublin
Your cart is empty.
Loading...